[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
RE: [cobalt-users] RaQ XTR:fan failure & highly loaded CPU
- Subject: RE: [cobalt-users] RaQ XTR:fan failure & highly loaded CPU
- From: "Richard Sidlin" <dns@xxxxxxxxxxxxxxxxx>
- Date: Fri Aug 31 04:32:38 2001
- List-id: Mailing list for users to share thoughts on Cobalt products. <cobalt-users.list.cobalt.com>
I had this on my XTR. It was recalled. How long have you had it?
-----Original Message-----
From: cobalt-users-admin@xxxxxxxxxxxxxxx
[mailto:cobalt-users-admin@xxxxxxxxxxxxxxx] On Behalf Of Etienne
Antoniutti Di Muro
Sent: 31 August 2001 10:39
To: cobalt-users@xxxxxxxxxxxxxxx
Cc: etienne@xxxxxxxxxxxxx
Subject: [cobalt-users] RaQ XTR:fan failure & highly loaded CPU
I (admin) received the attached mail messages from the RaQ XTR. The "C"
Logo Badge started blinking and all services (web,mail,ftp,telnet) were
suspended. I needed to force the RaQ to power down as it was not
responding. The server is a new machine, up since a month, can't believe
that ALL 6 fans failed simultaneously.
The machine is receiving about 100 web hits per day.
Actually room temperature is quite hot (30+ deg C = 86+ deg F), maybe
the cause is that the operating anvirorment conditions were close to the
limit?? Anyway, why was the CPU loaded with all services suspended?
any idea?
tnks in advance
etienne
--------------
Original Msg no1
From:admin
To: sys
Subject:One or more fans have failed
One or more fans have failed. These fans should be replaced immediately
to avoid overheating. See below for a listing of the problematic fans.
There are six fans which are located in the middle of the unit in two
groups of three, directly behind the drive bays. Fans 1-3 are located
between the drive bays and the CPU(s) on the left side of the box, when
facing the front panel. Fan 1 is near the edge, fan 2 is in the middle,
and fan 3 is toward the center of the box. Fans 4-6 are located on the
right side of the box, between the drive bays and the power supply. Fan
4 is toward the center of the box, fan 5 is in the middle, and fan 6 is
nearest the edge of the box.
Consult your documentation for instructions on how to replace the fans.
Below is a detailed listing of each fan's speed in revolutions per
minute and an indication of the acceptibility of that speed.
Fan # RPM Status
__________________________
Fan 1: 5699 FAILED
Fan 2: 5699 FAILED
Fan 3: 5399 FAILED
Fan 4: 5399 FAILED
Fan 5: 5099 FAILED
Fan 6: 5399 FAILED
---------------
Original Msg no2
From: admin
To:sys
Subject:CPU has been heavily loaded.
Over the past fifteen minutes, the CPU has been heavily loaded.
This will result in noticible performace loss. Consider moving some of
the services to other Cobalt servers, or reduce the complexity of the
CGI scripts running on the Cobalt server itself.
1 minute load average: 14.99
5 minute load average: 14.88
15 minute load average: 14.15
_______________________________________________
cobalt-users mailing list
cobalt-users@xxxxxxxxxxxxxxx
To Subscribe or Unsubscribe, please go to:
http://list.cobalt.com/mailman/listinfo/cobalt-users