[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: [cobalt-users] problem with disk integrity
- Subject: Re: [cobalt-users] problem with disk integrity
- From: Gerald Waugh <gwaugh@xxxxxxxxxxxxxxxxxxxxxxx>
- Date: Fri Apr 18 06:29:02 2003
- Organization: Front Street Networks LLC
- List-id: Mailing list for users to share thoughts on Sun Cobalt products. <cobalt-users.list.cobalt.com>
On Friday 18 April 2003 01:39, Martin Stacey wrote:
> I periodically get this message from my RAQ550
>
> Summary of changes:
>
> * There is a problem with disk integrity.
> - The system is resynchronizing the information on the disks. Please
> look at the Disk Integrity entry in Active Monitor for more information.
> - Drive self monitoring is performing normally on all installed
> drives.
> - DMA is performing normally.
>
> However looking in the active monitor shows nothing amiss
>
> Approx 15 mins later I get the message
>
> Active Monitor has detected recent changes in the state of your server
> appliance.
> For more details, please see the Active Monitor section of the Server
> Desktop.
>
> Summary of changes:
>
> * Disks are functioning normally.
> - Disk mirroring is enabled and currently active.
> - Drive self monitoring is performing normally on all installed
> drives.
> - DMA is performing normally.
>
> Anybody else seen this or now of a fix ?
>
It's normal, when the disk are resyncing, you get the message.
When they are done resyncing you get the other message.
What you worry about is not getting the second message.
Gerald
--
http://frontstreetnetworks.com http://raqware.com
Front Street Networks LLC | Phone: 203-785-0699
229 Front Street, Ste C, New Haven, CT 06513-3203