[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

RE: [cobalt-users] RAQ4R Lockup/Crash and Over Heating??



Thanks... sounds like it might be useful.

Jerry

-----Original Message-----
From: cobalt-users-admin@xxxxxxxxxxxxxxx
[mailto:cobalt-users-admin@xxxxxxxxxxxxxxx]On Behalf Of Andy Brown
Sent: Tuesday, December 10, 2002 3:57 AM
To: cobalt-users@xxxxxxxxxxxxxxx
Subject: Re: [cobalt-users] RAQ4R Lockup/Crash and Over Heating??


<snip>
On Monday 09 December 2002 10:29 pm, Jerry Farquhar wrote:
> Had a Raq4r decide to quit functioning this morning in the wee hours and
> upon initial inspection it felt unusually warm in comparison to another
> identical RA4R.  The fans had recently been replaced and were blowing full
> force but seem much warmer than the other RAQ4R.
</snip>

Just FYI I have a small shell script that I run in cron.quarter-hourly/ to
check the CPU temp, and email if it raises above the set value. Handy to
tell
if a fan fails, or in this case too much load, etc hits the unit and the
temperature goes skyward. Follow my sig and choose downloads. Script is
called cpuinfo.sh
Tested on RaQ3 & 4 works nicely here, and has saved a RaQ from meltdown
before
(how unlucky is it for both fans to stop at the same time!)

Regards,
Andy
andy@xxxxxxxxxx
http://www.raqpak.com/  <-- Free PKGs, FAQs and scripts for Cobalt Raq
products.


_____________________________________
cobalt-users mailing list
cobalt-users@xxxxxxxxxxxxxxx
To subscribe/unsubscribe, or to SEARCH THE ARCHIVES, go to:
http://list.cobalt.com/mailman/listinfo/cobalt-users