Re: [cobalt-users] Raq550: How do I change Master SOA Serial Number
- Subject: Re: [cobalt-users] Raq550: How do I change Master SOA Serial Number
- From: Andy Brown <andy.brown@xxxxxxxxxxxxx>
- Date: Fri Nov 22 02:55:01 2002
- Organization: Interv8 Ltd
- List-id: Mailing list for users to share thoughts on Sun Cobalt products. <cobalt-users.list.cobalt.com>
<snip>
On Thursday 21 November 2002 3:58 pm, John D. Gorena wrote:
> I had to do a complete Restore from the CD to get my Raq550 working
> again. Now others are telling me that the SOA serial Number is very old
> and that is why nothing seems to be working when I make changes. How do
> I change the Master SOA Serial Number so that it is newer than anything
> cached? This number has to be located somewhere. It is not in the GUI.
</snip>
I'm not 100% on how the gui decides on the serial, but you can ssh in and
change them manually.
Go into /etc/named
and you'll see all the pri. files in there.
Open one up with pico or vi and look for the serial, increment as needed.
Although i'm not sure if the cobalt GUI will read this back in and increment,
or if it uses another number stored within its internal db's or somewhere
else.
Regards,
Andy
andy@xxxxxxxxxx
http://www.raqpak.com